EVN User Experiment Pipeline Feedback


Pipeline feedback for experiment EA056A. If you have any comments on this experiment please email the address below.
A detailed description of the pipeline output is available.


Last updated: Fri Mar 6 18:21:54 CET 2015 duev@jive.nl


General Comments. ( Brief data summary and scan listing )
EA056A had 12 stations, 16 16MHz IFs, 4 polarizations, 32 frequency points per IF/pol, and 2s integrations. The SOLINT was set to the scan length. Ef was used as the reference station. The fringe-finder and bandpass calibrators were '1923+210' and '1929+226'. The target source 'J1943+213' was calibrated using the phase-reference source '1932+204'.

The EVN reliability indicator (ERI) for this experiment was ERI = 0.96 . ERI* = 0.97 . (Sv=0.5)


Plots of the autocorrelations
Comments.
Each scan plotted separately, all stations.


plots of the uncalibrated amplitude and phase against time
Comments.
Full-experiment for Ef-* baselines, no calibration applied. A 2 minute plot-averaging was used.


Plots of the uncalibrated amplitude and phase against frequency channel
Comments.
Scalar averaged Ef-* baselines, each scan plotted separately. No calibration applied yet.


The uncalibrated amplitude and phase of the crosshand correlations against frequency channel
Comments.


TSYS against time
Comments.
TY1 table, each IF/pol on a separate plot.


Telescope sensitivities from the a priori TSYS and Gain curves (the square of this number gives the antenna noise (SEFD) in Jy - the smaller the better).
Comments.
Gain amplitude from CL2 table.


Fringe-fit phase solutions (including Parallactic Angle correction).
Comments.
CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2.


Fringe-fit delay solutions
Comments.
SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot.


Fringe-fit rate solutions
Comments.
SN2 station rate solutions.


Telescope bandpasses
Comments.
Bandpass table 1. 1923+210 and 1929+226 were used for bandpass calibration.


Calibrated amplitude and phase against time (a priori amplitude calibration and fringe-fit solutions applied).
Comments.
Full-experiment for Ef-* baselines, calibrated with CL3.


Calibrated amplitude and phase against frequency channel
Comments.
Ef-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps.


Naturally weighted dirty map (not useful for bright sources) produced before self-cal of:
1929+226: pdf (not available) , or FITS (not available) .
1923+210: pdf (not available) , or FITS (not available) .
1932+204: pdf (not available) , or FITS (not available) .
J1943+213: pdf , or FITS .
Comments.


Uniformly weighted dirty map (not useful for bright sources) produced before self-cal of:
1929+226: pdf (not available) , or FITS (not available) .
1923+210: pdf (not available) , or FITS (not available) .
1932+204: pdf (not available) , or FITS (not available) .
J1943+213: pdf , or FITS .
Comments.


Phase corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
1929+226 .
1923+210 .
1932+204 .
J1943+213 (not available) .
Comments.
Plots of post-SPLIT tables SN1 for the sources that have been individually fringed.


Amplitude corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
1929+226: pdf , or text file , or statistical summary .
1923+210: pdf , or text file , or statistical summary .
1932+204: pdf , or text file , or statistical summary .
J1943+213: pdf (not available) , or text file (not available) , or statistical summary (not available) .
Comments.
As above, but for the post-SPLIT table SN2.


Telescope sensitivities (the total AMP gain applied during both a priori and self calibration; the square of this number gives the antenna noise (SEFD) in Jy).
Comments.
CL4 gain-amp.


Residual closure phase (visibility closure phase with model closure phase subtracted) for:
1929+226 .
1923+210 .
1932+204 .
J1943+213 (not available) .
Comments.
Separate files per (fringed) source, showing closure phase plots for all the triangles. Only stokes=I shown.


Calibrated visibilities and the source model of:
1929+226 .
1923+210 .
1932+204 .
J1943+213 (not available) .
Comments.
For each (fringed) source, plots of amp/phase on Ef-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted.


Calibrated visibilities against u,v distance for:
1929+226: pdf , or png .
1923+210: pdf , or png .
1932+204: pdf , or png .
J1943+213: pdf , or png .
Comments.
For each source, a plot of amp vs. |uv| distance.


u,v coverage for:
1929+226: pdf , or png .
1923+210: pdf , or png .
1932+204: pdf , or png .
J1943+213: pdf , or png .
Comments.
For each source, a plot of the u-v coverage.


Crude maps of sources:
1929+226: pdf , or FITS .
1923+210: pdf , or FITS .
1932+204: pdf , or FITS .
J1943+213: pdf , or FITS .
Comments.
For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script.