GENERAL EB039F had 10 stations, 8 8MHz IFs, and two polarizations. There were four passes; this pipelining corresponds to the geodetic pass, with 32 frequency points per IF, 2 pol, and 2s integrations. Considerably more information is included in the experiment's cover letter on the standard-plots portion of the EVN Archive. The SOLINT was 1.5 minutes. Tr was used as the reference station. /// ERIVAL 0.831 /// ERISTAR 0.831 /// ERICOMM The ERI for the geodetic pass was 0.831 The losses include times in which Wb and Ys were out in the first geodetic block, plus Jb having no response in IF3-4/L. Only EVN stations contributed to the ERI calculation. The ERI and ERI* for the whole experiment, weighted by time over the four passes were 0.809 and 0.839. /// POSSM_AUTOCORR Each scan plotted separately, all stations. /// VPLOT_UNCAL Full-experiment for Tr-* baselines, no calibration applied. A 1.5 minute plot-averaging was used. /// POSSM_UNCAL Scalar averaged Tr-* baselines, each scan plotted separately. No calibration applied yet. /// POSSM_CPOL /// TSYS TY1 table, each IF/pol on a separate plot. Each pass has its own edited a antab file, with INDEX lines reflecting the IF(s)/pol present in it data. /// GAIN Gain amplitude from CL2 table. /// FRING_DELAY SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot. Most IF/pols in On have an outlier scan in the first block (resid.delay ~1us). For this experiment, one lag corresponds to 1/16 microsecond of delay. /// FRING_RATE SN2 station rate solutions. Ef has obvious outliers in the first scan in makes in the first block; On has the same outlier scan as for delays. /// FRING_PHAS CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2. /// BANDPASS Bandpass table 1. 1550+052 and 0555+394 were used for bandpass calibration. /// VPLOT_CAL Full-experiment for Tr-* baselines, calibrated with CL3. The 1-min plot-averaging still applied. /// POSSM_CAL Tr-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps. /// IMAPN /// IMAPU /// CALIB_PHAS1 Plots of post-SPLIT tables SN1 for the sources that have been individually fringed. /// CALIB_AMP2 As above, but for the post-SPLIT table SN2. /// SENS CL4 gain-amp. /// CLPHS Separate files per (fringed) source, showing closure phase plots for all the triangles (not just Tr-*-*). Only stokes=I shown. /// VPLOT_MODEL For each (fringed) source, plots of amp/phase on Tr-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted. /// UVCOV For each source, a plot of the u-v coverage. /// UVPLT For each source, a plot of amp vs. |uv| distance. /// ICLN For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script. ///