GENERAL EG040E had 10 stations, 8 16 MHz IFs, four polarizations, and used 32 frequency points per IF/pol, with 2s integrations. Considerably more information is included in the experiment's cover letter on the standard-plots portion of the EVN Archive. In the pipelining, the target sources were treated as phase-referenced sources and not directly fringed. The SOLINT was set automatically at a representative length of a reference-source scan in a phase-reference cycle (90s judging from the schedule). Ef & Wb were used as the reference stations (Wb for the time that Ef was doing pointing checks) /// ERIVAL 0.8 /// ERISTAR 0.8 /// ERICOMM The ERI was 0.8, with losses from Mc with no fringes for the entire experiment. /// POSSM_AUTOCORR Each scan plotted separately, all stations. /// VPLOT_UNCAL Full-experiment for Ef-* baselines, no calibration applied. A 2.1 minute plot-averaging was used. /// POSSM_UNCAL Scalar averaged Ef-* baselines, each scan plotted separately. No calibration applied yet. /// POSSM_CPOL Scalar averaged Ef-* baselines for LR, each scan plotted separately. No calibration applied yet. /// TSYS TY1 table, each IF/pol on a separate plot. /// GAIN Gain amplitude from CL2 table. /// FRING_DELAY SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot. /// FRING_RATE SN2 station rate solutions. /// FRING_PHAS CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2. /// BANDPASS Bandpass table 1. 3C274 and 3C345 were used for bandpass calibration. /// VPLOT_CAL Full-experiment for Ef-* baselines, calibrated with CL3. The 2.1-min plot-averaging still applied. /// POSSM_CAL Ef-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps. /// IMAPN Naturually weighted dirty map of the targets. /// IMAPU Uniformly weighted dirty map of the targets. /// CALIB_PHAS1 Plots of post-SPLIT tables SN1 for the sources. /// CALIB_AMP2 As above, but for the post-SPLIT table SN2. /// SENS CL4 gain-amp. /// CLPHS Separate files per (fringed) source, showing closure phase plots for all the triangles (not just Ef-*-*). Only stokes=I shown. /// VPLOT_MODEL For each (fringed) source, plots of amp/phase on Ef-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted. /// UVCOV For each source, a plot of the u-v coverage. /// UVPLT For each source, a plot of amp vs. |uv| distance. /// ICLN For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script. ///