EVN User Experiment Pipeline Feedback


Pipeline feedback for experiment EI012D. If you have any comments on this experiment please email the address below.
A detailed description of the pipeline output is available.


Last updated: Wed Sep 23 16:54:23 CEST 2015 mao@jive.eu


General Comments. ( Brief data summary and scan listing )
C band phase-referencing experiment, observed on 9 Mar 2015. Data rate was 1 Gbps (8 X 16 MHz subbands, dual polarization, two-bit sampling). The target source HBOOTES2 was calibrated using the phase-reference source J1426+3625. J1159+2914, 3C286, Q208 were the fringe finders.
14 stations scheduled, however only 13 stations recorded useful data.

The EVN reliability indicator (ERI) for this experiment was ERI = 0.86 . ERI* = 0.86 . The ERI* value takes into account that:
- Ur data was recorded incorrectly
The ERI value also takes into account losses that are outside the station's control, of which there were none for this experiment.


Plots of the autocorrelations
Comments.
Each scan plotted separately, all stations. There is an RFI(?) peak visible in 5L for NT, YS and ZC.


plots of the uncalibrated amplitude and phase against time
Comments.
Full-experiment for Ef-* baselines, no calibration applied. A 1.5 minute plot-averaging was used.


Plots of the uncalibrated amplitude and phase against frequency channel
Comments.
Scalar averaged Ef-* baselines, each scan plotted separately. No calibration applied yet.


The uncalibrated amplitude and phase of the crosshand correlations against frequency channel (not available)
Comments.
No cross-pols for this experiment


TSYS against time
Comments.
TY1 table, each IF/pol on a separate plot. SV, ZC, and BD receive "default" antab values.


Telescope sensitivities from the a priori TSYS and Gain curves (the square of this number gives the antenna noise (SEFD) in Jy - the smaller the better).
Comments.
Gain amplitude from CL2 table.


Fringe-fit phase solutions (including Parallactic Angle correction).
Comments.
CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2.


Fringe-fit delay solutions
Comments.
SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot.


Fringe-fit rate solutions
Comments.
SN2 station rate solutions.


Telescope bandpasses
Comments.
Bandpass table 1. OQ208 and J1159+2914 were used for bandpass calibration. NT L looks a bit odd.


Calibrated amplitude and phase against time (a priori amplitude calibration and fringe-fit solutions applied).
Comments.
Full-experiment for Ef-* baselines, calibrated with CL3. A 1.5 minute plot-averaging was used.


Calibrated amplitude and phase against frequency channel
Comments.
Ef-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps.


Naturally weighted dirty map (not useful for bright sources) produced before self-cal of:
J1159+2914: pdf (not available) , or FITS (not available) .
OQ208: pdf (not available) , or FITS (not available) .
3C286: pdf (not available) , or FITS (not available) .
HBOOTES2: pdf , or FITS .
J1426+3625: pdf (not available) , or FITS (not available) .
Comments.
Naturally weighted dirty maps of phase-referenced sources.


Uniformly weighted dirty map (not useful for bright sources) produced before self-cal of:
J1159+2914: pdf (not available) , or FITS (not available) .
OQ208: pdf (not available) , or FITS (not available) .
3C286: pdf (not available) , or FITS (not available) .
HBOOTES2: pdf , or FITS .
J1426+3625: pdf (not available) , or FITS (not available) .
Comments.
Uniformly weighted dirty maps of phase-referenced sources.


Phase corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
J1159+2914 .
OQ208 .
3C286 .
HBOOTES2 (not available) .
J1426+3625 .
Comments.
Plots of post-SPLIT tables SN1 for the sources that have been individually fringed.


Amplitude corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
J1159+2914: pdf , or text file , or statistical summary .
OQ208: pdf , or text file , or statistical summary .
3C286: pdf , or text file , or statistical summary .
HBOOTES2: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J1426+3625: pdf , or text file , or statistical summary .
Comments.
As above, but for the post-SPLIT table SN2.


Telescope sensitivities (the total AMP gain applied during both a priori and self calibration; the square of this number gives the antenna noise (SEFD) in Jy).
Comments.
CL4 gain-amp.


Residual closure phase (visibility closure phase with model closure phase subtracted) for:
J1159+2914 .
OQ208 .
3C286 .
HBOOTES2 (not available) .
J1426+3625 .
Comments.
Separate files per (fringed) source, showing closure phase plots for all the triangles. Only stokes=I shown.


Calibrated visibilities and the source model of:
J1159+2914 .
OQ208 .
3C286 .
HBOOTES2 (not available) .
J1426+3625 .
Comments.
For each (fringed) source, plots of amp/phase on Ef-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted.


Calibrated visibilities against u,v distance for:
J1159+2914: pdf , or png .
OQ208: pdf , or png .
3C286: pdf , or png .
HBOOTES2: pdf , or png .
J1426+3625: pdf , or png .
Comments.
For each source, a plot of amp vs. |uv| distance. The plot for HBOOTES looks odd...(more flux on _longer_ baselines?!)


u,v coverage for:
J1159+2914: pdf , or png .
OQ208: pdf , or png .
3C286: pdf , or png .
HBOOTES2: pdf , or png .
J1426+3625: pdf , or png .
Comments.
For each source, a plot of the u-v coverage.


Crude maps of sources:
J1159+2914: pdf , or FITS .
OQ208: pdf , or FITS .
3C286: pdf , or FITS .
HBOOTES2: pdf , or FITS .
J1426+3625: pdf , or FITS .
Comments.
For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script.