GENERAL EP075D had 11 stations, 8 x 16 MHz IFs, 4 polarizations, and used 32 frequency points per IF/pol, with 2s integrations. It was correlated twice for two different target phase centers, ARP299A and ARP299B. In the pipelining, the target sources were treated as phase-referenced and not directly fringed. The SOLINT was automatically set at 0.505 min. Ef and Wb were used as the reference stations. The target sources 'ARP299A' and 'ARP299B' were calibrated using the phase-reference source 'J1128+5925'. The fringe-finder and bandpass calibrator was '4C39.25'. /// ERIVAL 0.992 /// ERISTAR 0.992 /// ERICOMM Losses: 22 min of Bd due to a Mk5 problem. /// POSSM_AUTOCORR Each scan plotted separately, all stations. /// VPLOT_UNCAL Full-experiment for Wb-* baselines, no calibration applied. A 2-minute plot-averaging was used. /// POSSM_UNCAL Scalar averaged Wb-* baselines, each scan plotted separately. No calibration applied yet. /// POSSM_CPOL /// TSYS TY1 table, each IF/pol on a separate plot. /// GAIN Gain amplitude from CL2 table. /// FRING_PHAS /// FRING_DELAY SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot. /// FRING_RATE SN2 station rate solutions. /// FRING_PHAS CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2. /// BANDPASS Bandpass table 1. /// VPLOT_CAL Full-experiment for Wb-* baselines, calibrated with CL3. The 2-min plot-averaging still applied. /// POSSM_CAL Wb-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps. /// IMAPN /// IMAPU /// CALIB_PHAS1 Plots of post-SPLIT tables SN1 for the sources. /// CALIB_AMP2 As above, but for the post-SPLIT table SN2. /// SENS CL4 gain-amp. /// CLPHS Separate files per (fringed) source, showing closure phase plots for all the triangles (not just Wb-*-*). Only stokes=I shown. /// VPLOT_MODEL For each (fringed) source, plots of amp/phase on Wb-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted. /// UVCOV For each source, a plot of the u-v coverage. /// UVPLT For each source, a plot of amp vs. |uv| distance. /// ICLN For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script. ///