EVN User Experiment Pipeline Feedback


Pipeline feedback for experiment EP075D_1. If you have any comments on this experiment please email the address below.
A detailed description of the pipeline output is available.


Last updated: Mon Aug 13 17:22:44 CEST 2012 pidopryhora@jive.nl


General Comments. ( Brief data summary and scan listing )
EP075D had 11 stations, 8 x 16 MHz IFs, 4 polarizations, and used 32 frequency points per IF/pol, with 2s integrations. It was correlated twice for two different target phase centers, ARP299A and ARP299B. In the pipelining, the target sources were treated as phase-referenced and not directly fringed. The SOLINT was automatically set at 0.505 min. Ef and Wb were used as the reference stations. The target sources 'ARP299A' and 'ARP299B' were calibrated using the phase-reference source 'J1128+5925'. The fringe-finder and bandpass calibrator was '4C39.25'.

The EVN reliability indicator (ERI) for this experiment was ERI = 0.992 . ERI* = 0.992 . Losses: 22 min of Bd due to a Mk5 problem.


Plots of the autocorrelations
Comments.
Each scan plotted separately, all stations.


plots of the uncalibrated amplitude and phase against time
Comments.
Full-experiment for Wb-* baselines, no calibration applied. A 2-minute plot-averaging was used.


Plots of the uncalibrated amplitude and phase against frequency channel
Comments.
Scalar averaged Wb-* baselines, each scan plotted separately. No calibration applied yet.


The uncalibrated amplitude and phase of the crosshand correlations against frequency channel
Comments.


TSYS against time
Comments.
TY1 table, each IF/pol on a separate plot.


Telescope sensitivities from the a priori TSYS and Gain curves (the square of this number gives the antenna noise (SEFD) in Jy - the smaller the better).
Comments.
Gain amplitude from CL2 table.


Fringe-fit phase solutions (including Parallactic Angle correction).
Comments.
FRING_PHAS CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2.


Fringe-fit delay solutions
Comments.
SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot.


Fringe-fit rate solutions
Comments.
SN2 station rate solutions.


Telescope bandpasses
Comments.
Bandpass table 1.


Calibrated amplitude and phase against time (a priori amplitude calibration and fringe-fit solutions applied).
Comments.
Full-experiment for Wb-* baselines, calibrated with CL3. The 2-min plot-averaging still applied.


Calibrated amplitude and phase against frequency channel
Comments.
Wb-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps.


Naturally weighted dirty map (not useful for bright sources) produced before self-cal of:
4C39.25: pdf (not available) , or FITS (not available) .
J1128+5925: pdf (not available) , or FITS (not available) .
ARP299A: pdf , or FITS .
Comments.


Uniformly weighted dirty map (not useful for bright sources) produced before self-cal of:
4C39.25: pdf (not available) , or FITS (not available) .
J1128+5925: pdf (not available) , or FITS (not available) .
ARP299A: pdf , or FITS .
Comments.


Phase corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
4C39.25 .
J1128+5925 .
ARP299A (not available) .
Comments.
Plots of post-SPLIT tables SN1 for the sources.


Amplitude corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
4C39.25: pdf , or text file , or statistical summary .
J1128+5925: pdf , or text file , or statistical summary .
ARP299A: pdf (not available) , or text file (not available) , or statistical summary (not available) .
Comments.
As above, but for the post-SPLIT table SN2.


Telescope sensitivities (the total AMP gain applied during both a priori and self calibration; the square of this number gives the antenna noise (SEFD) in Jy).
Comments.
CL4 gain-amp.


Residual closure phase (visibility closure phase with model closure phase subtracted) for:
4C39.25 .
J1128+5925 .
ARP299A (not available) .
Comments.
Separate files per (fringed) source, showing closure phase plots for all the triangles (not just Wb-*-*). Only stokes=I shown.


Calibrated visibilities and the source model of:
4C39.25 .
J1128+5925 .
ARP299A (not available) .
Comments.
For each (fringed) source, plots of amp/phase on Wb-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted.


Calibrated visibilities against u,v distance for:
4C39.25: pdf , or png .
J1128+5925: pdf , or png .
ARP299A: pdf , or png .
Comments.
For each source, a plot of amp vs. |uv| distance.


u,v coverage for:
4C39.25: pdf , or png .
J1128+5925: pdf , or png .
ARP299A: pdf , or png .
Comments.
For each source, a plot of the u-v coverage.


Crude maps of sources:
4C39.25: pdf , or FITS .
J1128+5925: pdf , or FITS .
ARP299A: pdf , or FITS .
Comments.
For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script.