The 'standard plots' for EV018D are as follows: ev018d-weight.ps station weight vs. time ev018d-auto-[1,2]{sep}.ps station autocorrelation amp vs. freq ev018d-cross-[1,2][a,p].ps baseline amp/phs vs. freq ev018d-ampphase-[1..4][a,p]{Wb}.ps Ef-* {or Wb-*} baseline amp/phs vs. time The auto and cross plots show data from scan 52 (J1800+3848) [1] and scan 220 (3C454.3) [2]. The ampphase plots show amp [a] or phase [p] vs. time, omitting target scans; ampphase plots [1]-[3] show data for the reference sources for the individual pulsars (1=B1929, 2=B2020, 3=B2021); plot [4] shows the whole experiment. For ampphase plot [3], there are also versions which show Wb-* baselines, since Ef misses the last ~1h20m of this pulsar. The antenna numbering in these plots is 0-based -- thus one less than the corresponding antenna numbers in the AIPS FITS file. (a) WEIGHT plots The plot shows the weights for all IFs (parallel-hands only) per station, with each 1s integration plotted as a separate ".". The IF/pol color-coding is: IF1/RR = red IF1/LL = blue IF2/RR = cyan IF2/LL = green IF3/RR = pink IF3/LL = med.grey IF4/RR = brown IF4/LL = purple IF5/RR = teal IF5/LL = yellow IF6/RR = steel blue IF6/LL = lt.grey IF7/RR = black IF7/LL = orange IF8/RR = lt.green IF8/LL = lt.purple (b) AUTOCORRELATION SPECTRA plots The plots show 2 minutes of data from the scans listed above. The IFs for a station are plotted side-by-side (the [2] plot with "sep" appended in the file-name place the IFs into separately-scaled plots to avoid peaks in one IF from throwing off the y-axis scale for other IFs). The polarization color-coding is RR=red, LL=blue. The y-axis ranges don't necessarily go down to zero. (c) BASELINE SPECTRA plots The baseline vs. frequency plots show vector-averaged amplitude and phase for all baselines for the same scans/data-intervals as the autocorrelation plots, with amp & phase going to separate plots using the same baseline lay-out on the page. The polarization color-coding remains RR=red, LL=blue. (d) AMP/PHASE(t) plots The baseline vs. time plots show amplitude and phase for non-target scans on Ef-* (and Wb-* for plot [3]), with amp & phase going to separate plots, and with time ranges described above. Each 1s integration is plotted as a separate ".", with the middle 80% of the band used for vector-averaging over frequency. The phase(t) plots show only RCP from IFs 1-3 to avoid the problems in Sv with in the upper 4 IFs (outside its top frequency), Zc in IF4 (up-converter RFI in band at 4979.9), and LCP for Tr in IFs 3-4 (dead BBC). The color-coding for the phase(t) plots is: IF1/RR = red IF2/RR = blue IF3/RR = cyan The amp(t) plots omit the fringe-finders to avoid throwing off the y-axis scale, with IF/pol color-coding the same as in the weight plot.