GENERAL GJ014 had 20 good stations, 8 16MHz IFs, 4 polarizations, 32 frequency points per IF/pol, and 2s integrations. Considerably more information is included in the experiment's cover letter on the standard-plots portion of the EVN Archive. In the pipelining, the target sources were treated as phase-reference targets and were not separately fringe-fit. The SOLINT was set to 2.5 minutes. Ef, then Ys (for EVN-only times when Ef was out), and then Nl (for VLBA-only times) were used as the reference stations. /// ERIVAL 0.726 /// ERISTAR 0.915 /// ERICOMM The losses include Sv having no signal in the RCP channels, Jb missing the whole experiment because of winds, and Ef missing 2.5hr also because of winds. The wind-related outages count against ERI but not ERI*. The ERI values pertain to only the EVN stations in the experiment. /// POSSM_AUTOCORR Each scan plotted separately, all stations. /// VPLOT_UNCAL Full-experiment for Ef-* and Nl-* baselines, no calibration applied. A 2.5-minute plot-averaging was used. /// POSSM_UNCAL Scalar averaged Ef-* and Nl-* baselines, each scan plotted separately. No calibration applied yet. /// POSSM_CPOL Scalar averaged Ef-* and Nl-* baselines showing LR, each scan plotted separately. No calibration applied yet. /// TSYS TY1 table, each IF/pol on a separate plot. /// GAIN Gain amplitude from CL2 table. /// FRING_DELAY SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot. Most of On data is gone after fringe-fitting. Only a few individual outliers (e.g., Hh IF6/R last solint). /// FRING_RATE SN2 station rate solutions. Stations involved in longer baselines show evolution of rate with time (likely arising from the double nature of the target) -- by the time Nl becomes the reference it's rate is around -15 mHz. /// FRING_PHAS CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2. /// BANDPASS Bandpass table 1. 3C345 was used for bandpass calibration. /// VPLOT_CAL Full-experiment for Ef-* and Nl-* baselines, calibrated with CL3. The 2.5-minute plot-averaging still applied. /// POSSM_CAL Ef-* and Nl-* baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps. /// IMAPN Naturally-weighted dirty maps of the phase-referenced-to sources. /// IMAPU Uniformly-weighted dirty maps of the phase-referenced-to sources. /// CALIB_PHAS1 Plots of post-SPLIT tables SN1 for the sources that have been individually fringed. /// CALIB_AMP2 As above, but for the post-SPLIT table SN2. /// SENS CL4 gain-amp. /// CLPHS Separate files per (fringed) source, showing closure phase plots for all the triangles. Only stokes=I shown. /// VPLOT_MODEL For each (fringed) source, plots of amp/phase on Ef-* and Nl-* baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted. /// UVCOV For each source, a plot of the u-v coverage. /// UVPLT For each source, a plot of amp vs. |uv| distance. The target has apparently excess flux density for |uv| longer than about 170 Mlambda (i.e., above the longest |uv| for 3C345). These issues can probably be improved with more careful calibration (no interactive SNSMO, SNEDT in the pipeline). /// ICLN For each source, a CLEAN map resulting from the automated fringing and self-cal iterations (or phase-referencing) in the pipeline script. ///