EVN User Experiment Pipeline Feedback


Pipeline feedback for experiment RSC04. If you have any comments on this experiment please email the address below.
A detailed description of the pipeline output is available.


Last updated: ma jan 28 16:17:42 CET 2019 immer@jive.eu


General Comments. ( Brief data summary and scan listing )
RSC04. L band e-EVN phase-referencing experiment, observed on 23 January 2019. The data rate was 1024 Mbps (8 x 16 MHz subbands, dual polarization, two-bit sampling). The target sources J1821+2633 and J1821+2635 were calibrated using the phase-reference source J1827+2638. The target sources J2052+4723A, J2052+4723B and J2053+4727 were calibrated using the phase-reference source J2102+4702. The target sources J2337+4830 and J2337+4825 were calibrated using the phase-reference source J2325+4806. J1801+4404 and J2236+2828 were observed as the calibrators and the fringe finders.
10 stations participated.

The EVN reliability indicator (ERI) for this experiment was ERI = . ERI* = .


Plots of the autocorrelations
Comments.
Each scan plotted separately, all stations.


Plots of the uncalibrated amplitude and phase against time
Comments.
Full-experiment for Ef-** baselines, no calibration applied. A 1.0 minute plot-averaging was used.


Plots of the uncalibrated amplitude and phase against frequency channel
Comments.
Scalar averaged Ef-** baselines, each scan plotted separately. No calibration applied yet.


The uncalibrated amplitude and phase of the crosshand correlations against frequency channel
Comments.


TSYS against time
Comments.
TY1 table, each IF/pol on a separate plot.


Telescope sensitivities from the a priori TSYS and Gain curves (the square of this number gives the antenna noise (SEFD) in Jy - the smaller the better).
Comments.
Gain amplitude from CL2 table.


Fringe-fit phase solutions (including Parallactic Angle correction).
Comments.
CL3 station phase solutions -- CL3 = CL2+SN2, thus also includes the initial amplitude/parallactic angle calibration from CL2 and the fringe solutions from SN2.


Fringe-fit delay solutions
Comments.
SN2 station delay solutions for the fringed sources, each IF/pol on a separate plot.


Fringe-fit rate solutions
Comments.
SN2 station rate solutions.


Telescope bandpasses
Comments.
Bandpass table 1. J1801+4404 and J2236+2828 were used for bandpass calibration.


Calibrated amplitude and phase against time (a priori amplitude calibration and fringe-fit solutions applied).
Comments.
Full-experiment for Ef-** baselines, calibrated with CL3. The 1.0-min plot-averaging still applied.


Calibrated amplitude and phase against frequency channel
Comments.
Ef-** baselines calibrated with CL3 and BP1. The amp and phase plots self-scale, not necessarily going down to 0 in the case of the amps.


Naturally weighted dirty map (not useful for bright sources) produced before self-cal of:
J1801+4404: pdf (not available) , or FITS (not available) .
J2337+4825: pdf , or FITS .
J1821+2633: pdf , or FITS .
J2052+4723B: pdf , or FITS .
J2337+4830: pdf , or FITS .
J2236+2828: pdf (not available) , or FITS (not available) .
J1821+2635: pdf , or FITS .
J2053+4727: pdf , or FITS .
J1827+2638: pdf (not available) , or FITS (not available) .
J2052+4723A: pdf , or FITS .
J2102+4702: pdf (not available) , or FITS (not available) .
J2325+4806: pdf (not available) , or FITS (not available) .
Comments.


Uniformly weighted dirty map (not useful for bright sources) produced before self-cal of:
J1801+4404: pdf (not available) , or FITS (not available) .
J2337+4825: pdf , or FITS .
J1821+2633: pdf , or FITS .
J2052+4723B: pdf , or FITS .
J2337+4830: pdf , or FITS .
J2236+2828: pdf (not available) , or FITS (not available) .
J1821+2635: pdf , or FITS .
J2053+4727: pdf , or FITS .
J1827+2638: pdf (not available) , or FITS (not available) .
J2052+4723A: pdf , or FITS .
J2102+4702: pdf (not available) , or FITS (not available) .
J2325+4806: pdf (not available) , or FITS (not available) .
Comments.


Phase corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
J1801+4404 .
J2337+4825 (not available) .
J1821+2633 (not available) .
J2052+4723B (not available) .
J2337+4830 (not available) .
J2236+2828 .
J1821+2635 (not available) .
J2053+4727 (not available) .
J1827+2638 .
J2052+4723A (not available) .
J2102+4702 .
J2325+4806 .
Comments.
Plots of post-SPLIT tables SN1 for the sources that have been individually fringed.


Amplitude corrections applied to a priori calibrated and fringe-fitted data by self-calibration.
J1801+4404: pdf , or text file , or statistical summary .
J2337+4825: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J1821+2633: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J2052+4723B: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J2337+4830: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J2236+2828: pdf , or text file , or statistical summary .
J1821+2635: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J2053+4727: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J1827+2638: pdf , or text file , or statistical summary .
J2052+4723A: pdf (not available) , or text file (not available) , or statistical summary (not available) .
J2102+4702: pdf , or text file , or statistical summary .
J2325+4806: pdf , or text file , or statistical summary .
Comments.
As above, but for the post-SPLIT table SN2.


Telescope sensitivities (the total AMP gain applied during both a priori and self calibration; the square of this number gives the antenna noise (SEFD) in Jy).
Comments.
CL4 gain-amp.


Residual closure phase (visibility closure phase with model closure phase subtracted) for:
J1801+4404 .
J2337+4825 (not available) .
J1821+2633 (not available) .
J2052+4723B (not available) .
J2337+4830 (not available) .
J2236+2828 .
J1821+2635 (not available) .
J2053+4727 (not available) .
J1827+2638 .
J2052+4723A (not available) .
J2102+4702 .
J2325+4806 .
Comments.
Separate files per (fringed) source, showing closure phase plots for all the triangles. Only stokes=I shown.


Calibrated visibilities and the source model of:
J1801+4404 .
J2337+4825 (not available) .
J1821+2633 (not available) .
J2052+4723B (not available) .
J2337+4830 (not available) .
J2236+2828 .
J1821+2635 (not available) .
J2053+4727 (not available) .
J1827+2638 .
J2052+4723A (not available) .
J2102+4702 .
J2325+4806 .
Comments.
For each (fringed) source, plots of amp/phase on Ef-** baselines, calibrated with (post-SPLIT) table CL3, with a model-line overplotted.


Calibrated visibilities against u,v distance for:
J1801+4404: pdf , or png .
J2337+4825: pdf , or png .
J1821+2633: pdf , or png .
J2052+4723B: pdf , or png .
J2337+4830: pdf , or png .
J2236+2828: pdf , or png .
J1821+2635: pdf , or png .
J2053+4727: pdf , or png .
J1827+2638: pdf , or png .
J2052+4723A: pdf , or png .
J2102+4702: pdf , or png .
J2325+4806: pdf , or png .
Comments.
For each source, a plot of amp vs. |uv| distance.


u,v coverage for:
J1801+4404: pdf , or png .
J2337+4825: pdf , or png .
J1821+2633: pdf , or png .
J2052+4723B: pdf , or png .
J2337+4830: pdf , or png .
J2236+2828: pdf , or png .
J1821+2635: pdf , or png .
J2053+4727: pdf , or png .
J1827+2638: pdf , or png .
J2052+4723A: pdf , or png .
J2102+4702: pdf , or png .
J2325+4806: pdf , or png .
Comments.
For each source, a plot of the u-v coverage.


Crude maps of sources:
J1801+4404: pdf , or FITS .
J2337+4825: pdf , or FITS .
J1821+2633: pdf , or FITS .
J2052+4723B: pdf , or FITS .
J2337+4830: pdf , or FITS .
J2236+2828: pdf , or FITS .
J1821+2635: pdf , or FITS .
J2053+4727: pdf , or FITS .
J1827+2638: pdf , or FITS .
J2052+4723A: pdf , or FITS .
J2102+4702: pdf , or FITS .
J2325+4806: pdf , or FITS .
Comments.
For each source, a CLEAN map resulting from the automated fringing and self-cal iterations in the pipeline script.